harmony 鸿蒙Battery Temperature Protection Customization
Battery Temperature Protection Customization
Overview
Introduction
OpenHarmony provides battery temperature protection by default. When a device is used in different environments, the battery temperature may become excessively high or low due to the impact of ambient environment. In such a case, the protection measures, for example, device shutdown, must be taken to ensure the device safety. However, the supported temperature range varies according to products. To address this issue, OpenHarmony provides the function of customizing the temperature range for battery protection.
Constraints
The configuration path for battery level customization is subject to the configuration policy. In this development guide, /vendor
is used as an example of the configuration path. During actual development, you need to modify the customization path based on the product configuration policy.
How to Develop
Setting Up the Environment
Hardware requirements:
Development board running the standard system, for example, the DAYU200 or Hi3516D V300 open source suite.
Environment requirements:
For details about the requirements on the Linux environment, see Quick Start.
Getting Started with Development
The following uses DAYU200 as an example to illustrate charging type customization.
Create the battery folder in the product directory /vendor/hihope/rk3568.
Create a target folder by referring to the default folder of power temperature projection configuration, and install it in
//vendor/hihope/rk3568/battery
. The content is as follows:profile ├── BUILD.gn ├── battery_config.json
Write the custom
battery_config.json
file by referring to thebattery_config.json
file in the default folder of power temperature projection configuration. For example:{ "temperature": { "high": 500, "low": -400 } }
Table 1 Description of temperature protection configuration |Temperature Protection Threshold|Temperature (°C)| |——–|——–| |high|600| |low|-500|
Write the
BUILD.gn
file by referring to theBUILD.gn
in the default folder of power temperature projection configuration to pack thebattery_config.json
file to the//vendor/etc/battery
directory. The configuration is as follows:import("//build/ohos.gni") # Reference build/ohos.gni. ohos_prebuilt_etc("battery_config") { source = "battery_config.json" relative_install_dir = "battery" install_images = [ chipset_base_dir ] # Required configuration for installing the battery_config.json file in the vendor directory. part_name = "product_rk3568" # Set part_name to product_rk3568 for subsequent build. }
Add the build target to
module_list
in ohos.build in the/vendor/hihope/rk3568
directory. For example:{ "parts": { "product_rk3568": { "module_list": [ "//vendor/hihope/rk3568/default_app_config:default_app_config", "//vendor/hihope/rk3568/image_conf:custom_image_conf", "//vendor/hihope/rk3568/preinstall-config:preinstall-config", "//vendor/hihope/rk3568/resourceschedule:resourceschedule", "//vendor/hihope/rk3568/etc:product_etc_conf", "//vendor/hihope/rk3568/battery/profile:battery_config" # Add the configuration for building of battery_config. ] } }, "subsystem": "product_hihope" }
In the preceding code,
//vendor/hihope/rk3568/battery/
is the folder path,profile
is the folder name, andbattery_config
is the build target.Build the customized version by referring to Quick Start.
./build.sh --product-name rk3568 --ccache
Burn the customized version to the DAYU200 development board.
Debugging and Verification
After startup, run the following command to launch the shell command line:
hdc shell
Go to the custom battery temperature configuration directory. The path of DAYU200 is used as an example.
cd /data/service/el0/battery/battery
Modify the battery temperature. The following uses the default power temperature protection configuration as an example.
echo 700 > temp
Report the battery information change to trigger temperature protection.
hidumper -s 3302 -a -r
The device is powered off.
Upon restarting, launch the shell command line, and modify the battery temperature.
echo -600 > temp
Report the battery information change to trigger temperature protection.
hidumper -s 3302 -a -r
The device is powered off.
Customize the temperature protection threshold configuration. For example:
{ "temperature": { "high": 500, "low": -400 } }
Modify the temperature protection threshold.
echo 550 > temp
Report the battery information change to trigger temperature protection.
hidumper -s 3302 -a -r
The device is powered off.
Upon restarting, launch the shell command line, and modify the temperature protection threshold.
echo -450 > temp
Report the battery information change to trigger temperature protection.
hidumper -s 3302 -a -r
The device is powered off.
Reference
During development, you can refer to the default power temperature protection configuration, as shown below:
{
"temperature": {
"high": 600,
"low": -500
}
}
Packing path: /system/etc/battery
你可能感兴趣的鸿蒙文章
harmony 鸿蒙AI Framework Development Guide
harmony 鸿蒙NNRt Access Adaptation
harmony 鸿蒙Application Privilege Configuration
harmony 鸿蒙Setting Up a Development Environment
harmony 鸿蒙Development Guidelines
harmony 鸿蒙Application Framework Overview
- 所属分类: 后端技术
- 本文标签:
热门推荐
-
2、 - 优质文章
-
3、 gate.io
-
8、 golang
-
9、 openharmony
-
10、 Vue中input框自动聚焦