harmony 鸿蒙Thermal Detection Customization
Thermal Detection Customization
Overview
Introduction
By default, OpenHarmony provides the thermal detection feature. A component, for example, the CPU or battery, generates heat while it is running. In this case, the component reports its temperature in real time through the corresponding temperature sensor. The thermal detection feature detects the temperature of components in real time and provides temperature input for the thermal management module. However, thermal detection on components varies according to product specifications. To address this issue, OpenHarmony provides the thermal detection customization function.
Constraints
The configuration path for battery level customization is subject to the configuration policy. In this development guide, /vendor
is used as an example of the configuration path. During actual development, you need to modify the customization path based on the product configuration policy.
How to Develop
Setting Up the Environment
Hardware requirements:
Development board running the standard system, for example, the DAYU200 or Hi3516D V300 open source suite.
Environment requirements:
For details about the requirements on the Linux environment, see Quick Start.
Getting Started with Development
The following uses DAYU200 as an example to illustrate thermal detection customization.
Create the
thermal
folder in the product directory /vendor/hihope/rk3568.Create a target folder by referring to the default thermal detection configuration folder, and install it in
//vendor/hihope/rk3568/thermal
. The content is as follows:profile ├── BUILD.gn ├── thermal_hdi_config.xml
Write the custom
thermal_hdi_config.xml
file by referring to the thermal_hdi_config.xml file in the default thermal detection configuration folder. The following table describes the related configuration items.Table 1 Configuration items for thermal detection
|Node|Configuration Item|Description|Value Type| |——–|——–|——–|——–| |item|tag|Temperature flag name of an actual or simulated node.|string| |item|value|Temperature flag value. Value 1 means to obtain the temperature of a simulated node, and the value 0, means to obtain the temperature of an actual node.|int| |group|name|Name of the actual or simulated node group.|string| |group|interval|Polling interval, in ms (default).|int| |thermal_zone|type|Thermal zone name.|string| |thermal_zone|path|Path for obtaining the thermal zone temperature of an actual node.|string| |thermal_node|type|Thermal node name.|string| |thermal_node|path|Path for obtaining the thermal node temperature of a simulated node.|string|
```shell
<base>
<item tag="sim_tz" value="0"/>
</base>
<polling>
<group name="actual" interval="30000">
<thermal_zone type="soc-thermal" path="sys/class/thermal/thermal_zone0/temp"/>
<thermal_zone type="gpu-thermal" path="sys/class/thermal/thermal_zone0/temp"/>
</group>
<group name="sim" interval="30000">
<thermal_node type="soc" path="data/service/el0/thermal/sensor/soc/temp"/>
<thermal_node type="cpu" path="data/service/el0/thermal/sensor/cpu/temp"/>
<thermal_node type="ap" path="data/service/el0/thermal/sensor/ap/temp"/>
<thermal_node type="pa" path="data/service/el0/thermal/sensor/pa/temp"/>
<thermal_node type="ambient" path="data/service/el0/thermal/sensor/ambient/temp"/>
<thermal_node type="charger" path="data/service/el0/thermal/sensor/charger/temp"/>
<thermal_node type="battery" path="data/service/el0/thermal/sensor/battery/temp"/>
<thermal_node type="shell" path="data/service/el0/thermal/sensor/shell/temp"/>
</group>
</polling>
```
For details about the path for obtaining the actual node temperature, see the path for obtaining the thermal zone temperature in [Thermal Log](https://www.seaxiang.com/blog/113fb66b8e26471a9d9c8970e5ee9cc9). For details about the path for obtaining the simulated node temperature, see [Default Thermal Detection Configuration](https://gitee.com/openharmony/drivers_peripheral/blob/master/thermal/interfaces/hdi_service/profile/thermal_hdi_config.xml).
Write the
BUILD.gn
file by referring to the BUILD.gn file in the default thermal detection configuration folder to pack thethermal_hdi_config.xml
file to the//vendor/etc/thermal_config/hdf
directory. The configuration is as follows:import("//build/ohos.gni") ohos_prebuilt_etc("thermal_hdf_config") { source = "thermal_hdi_config.xml" relative_install_dir = "thermal_config/hdf" install_images = [ chipset_base_dir ] # Required configuration for installing the thermal_hdi_config.xml file in the vendor directory. part_name = "product_rk3568" # Set part_name to product_rk3568 for subsequent build. You can change it as required. }
Add the build target to
module_list
in ohos.build in the/vendor/hihope/rk3568
directory. For example:{ "parts": { "product_rk3568": { "module_list": [ "//vendor/hihope/rk3568/default_app_config:default_app_config", "//vendor/hihope/rk3568/image_conf:custom_image_conf", "//vendor/hihope/rk3568/preinstall-config:preinstall-config", "//vendor/hihope/rk3568/resourceschedule:resourceschedule", "//vendor/hihope/rk3568/etc:product_etc_conf", "//vendor/hihope/rk3568/thermal/profile:thermal_hdf_config", // Add the configuration for building of thermal_hdf_config. ] } }, "subsystem": "product_hihope" }
In the preceding code,
//vendor/hihope/rk3568/thermal/
is the folder path,profile
is the folder name, andthermal_hdf_config
is the build target.Build the customized version by referring to Quick Start.
./build.sh --product-name rk3568 --ccache
Burn the customized version to the DAYU200 development board.
Debugging and Verification
After startup, run the following command to launch the shell command line:
hdc shell
Obtain the thermal detection result of the thermal zone.
hidumper -s 3303 -a -t
The following is the reference thermal detection result of the thermal zone. The value of Temperature is in unit of 0.001°C by default.
-------------------------------[ability]------------------------------- ----------------------------------ThermalService--------------------------------- ········· (Only the thermal detection result is displayed here. Other information is omitted.) Type: gpu-thermal Temperature: 35555 Type: soc-thermal Temperature: 35000 ······
Reference
During development, you can refer to the default thermal detection configuration.
Packing path: /vendor/etc/thermal_config/hdf
你可能感兴趣的鸿蒙文章
harmony 鸿蒙AI Framework Development Guide
harmony 鸿蒙NNRt Access Adaptation
harmony 鸿蒙Application Privilege Configuration
harmony 鸿蒙Setting Up a Development Environment
harmony 鸿蒙Development Guidelines
harmony 鸿蒙Application Framework Overview
- 所属分类: 后端技术
- 本文标签:
热门推荐
-
2、 - 优质文章
-
3、 gate.io
-
8、 golang
-
9、 openharmony
-
10、 Vue中input框自动聚焦