harmony 鸿蒙Thermal Level Customization
Thermal Level Customization
Overview
Introduction
By default, OpenHarmony provides the thermal level feature. Different hardware devices generate different amounts of heat and can tolerate different maximum temperatures. Therefore, for different components, the thermal level standard needs to be defined based on their temperatures to clearly indicate the thermal status and provide input for thermal control. However, the thermal level of components at different temperatures varies according to product specifications. To address this issue, OpenHarmony provides the thermal level customization function.
Constraints
The configuration path for battery level customization is subject to the configuration policy. In this development guide, /vendor
is used as an example of the configuration path. During actual development, you need to modify the customization path based on the product configuration policy.
How to Develop
Setting Up the Environment
Hardware requirements:
Development board running the standard system, for example, the DAYU200 or Hi3516D V300 open source suite.
Environment requirements:
For details about the requirements on the Linux environment, see Quick Start.
Getting Started with Development
The following uses DAYU200 as an example to illustrate thermal level customization.
Create the
thermal
folder in the product directory /vendor/hihope/rk3568.Create a target folder by referring to the default thermal level configuration folder, and install it in
//vendor/hihope/rk3568/thermal
. The content is as follows:profile ├── BUILD.gn ├── thermal_service_config.xml
Write the custom
thermal_service_config.xml
file by referring to the thermal_service_config.xml file in the default thermal level configuration folder. The following tables describe the related configuration items.Table 1 Description of the base configuration |Configuration Item|Description|Parameter|Parameter Description|Type|Value Range| |——–|——–|——–|——–|——–|——–| |tag=“history_temp_count”|Name of the tag indicating the number of historical temperature reporting times.|value|Number of historical temperature reporting times.|int|>0| |tag=“temperature_query_enum”|Tag name of the device list for obtaining the temperature.|value|Device list for obtaining the temperature.|enum|soc, battery, shell, cpu, charger, ambient, ap, and pa|
Table 2 Description of the sensor_cluster configuration
|Configuration Item|Description|Data Type|Value Range| |——–|——–|——–|——–| |name|Sensor cluster name|string|None| |sensor|Sensors in the cluster|string|soc, battery, shell, cpu, charger, ambient, ap, and pa| |aux_sensor|Auxiliary sensors in the cluster|string|soc, battery, shell, cpu, charger, ambient, ap, and pa|
**Table 3** Description of the item configuration
|Configuration Item|Description|Data Type|Value Range| |——–|——–|——–|——–| |level|Thermal level defined for each sensor cluster|int|>0| |threshold|Temperature threshold for each sensor in the cluster to reach the corresponding thermal level. The value is in unit of 0.001°C by default and can be changed as needed.|int|Product-specific| |threshold_clr|Temperature threshold for each sensor in the cluster to roll back to the previous thermal level.|int|Product-specific| |temp_rise_rate|Temperature rise frequency.|double|Product-specific|
```shell
<thermal version="0.01" product="lya">
<base>
<item tag="history_temp_count" value="10"/>
<item tag="temperature_query_enum" value="soc,battery,shell,cpu,charger,ambient,ap,pa"/>
</base>
<level>
<sensor_cluster name="base_safe" sensor="battery,charger,cpu,soc">
<item level="1" threshold="42000,40000,30000,40000" threshold_clr="38000,36000,28000,38000"/>
<item level="2" threshold="43000,41000,32000,42000" threshold_clr="41000,39000,30000,40000"/>
<item level="3" threshold="46000,44000,34000,44000" threshold_clr="44000,42000,32000,42000"/>
<item level="4" threshold="48000,46000,36000,46000" threshold_clr="46000,44000,34000,44000"/>
</sensor_cluster>
</level>
```
Write the
BUILD.gn
file by referring to the BUILD.gn file in the default thermal level configuration folder to pack thethermal_service_config.xml
file to the/vendor/etc/thermal_config
directory. The configuration is as follows:import("//build/ohos.gni") # Reference build/ohos.gni. ohos_prebuilt_etc("thermal_service_config") { source = "thermal_service_config.xml" relative_install_dir = "thermal_config" install_images = [ chipset_base_dir ] # Required configuration for installing the thermal_service_config.xml file in the vendor directory. part_name = "product_rk3568" # Set part_name to product_rk3568 for subsequent build. You can change it as required. }
Add the build target to
module_list
in ohos.build in the/vendor/hihope/rk3568
directory. For example:{ "parts": { "product_rk3568": { "module_list": [ "//vendor/hihope/rk3568/default_app_config:default_app_config", "//vendor/hihope/rk3568/image_conf:custom_image_conf", "//vendor/hihope/rk3568/preinstall-config:preinstall-config", "//vendor/hihope/rk3568/resourceschedule:resourceschedule", "//vendor/hihope/rk3568/etc:product_etc_conf", "//vendor/hihope/rk3568/thermal/profile:thermal_service_config", // Add the configuration for building of thermal_service_config. ] } }, "subsystem": "product_hihope" }
In the preceding code,
//vendor/hihope/rk3568/thermal/
is the folder path,profile
is the folder name, andthermal_service_config
is the build target.Build the customized version by referring to Quick Start.
./build.sh --product-name rk3568 --ccache
Burn the customized version to the DAYU200 development board.
Debugging and Verification
After startup, run the following command to launch the shell command line:
hdc shell
Go to the
data/service/el0/thermal/sensor/soc/
directory.cd data/service/el0/thermal/sensor/soc
Change the SOC temperature.
echo 42000 > temp
Obtain the current thermal level information.
hidumper -s 3303 -a -l
The following is the reference thermal level information after customization:
-------------------------------[ability]------------------------------- ----------------------------------ThermalService--------------------------------- name: base_safe level: 2 name: cold_safe level: 0 name: high_safe level: 0 name: warm_5G level: 0 name: warm_safe level: 1
Reference
During development, you can refer to the default thermal level configuration.
Packing path: /vendor/etc/thermal_config/hdf
你可能感兴趣的鸿蒙文章
harmony 鸿蒙AI Framework Development Guide
harmony 鸿蒙NNRt Access Adaptation
harmony 鸿蒙Application Privilege Configuration
harmony 鸿蒙Setting Up a Development Environment
harmony 鸿蒙Development Guidelines
harmony 鸿蒙Application Framework Overview
- 所属分类: 后端技术
- 本文标签:
热门推荐
-
2、 - 优质文章
-
3、 gate.io
-
8、 golang
-
9、 openharmony
-
10、 Vue中input框自动聚焦