4600101 Service Connection Failure

Error Message

Failed to connect to the service.

Description

This error code is reported if a service connection failure occurs.

Possible causes

  1. The system service stops running.

  2. The internal communication of system services is abnormal.

Solution

Check whether the system services are running properly.

  1. Run the following command on the console to view the current system service list:

    > hdc shell hidumper -ls
    
  2. Check whether Battery-info is included in the system service list.